Merge branch 'obsd-master'

pull/1041/merge
Thomas Adam 2017-08-17 12:01:17 +01:00
commit 07a13697e1
3 changed files with 28 additions and 6 deletions

View File

@ -90,8 +90,10 @@ alerts_check_session(struct session *s)
static int
alerts_enabled(struct window *w, int flags)
{
if (flags & WINDOW_BELL)
return (1);
if (flags & WINDOW_BELL) {
if (options_get_number(w->options, "monitor-bell"))
return (1);
}
if (flags & WINDOW_ACTIVITY) {
if (options_get_number(w->options, "monitor-activity"))
return (1);
@ -164,6 +166,8 @@ alerts_check_bell(struct window *w)
if (~w->flags & WINDOW_BELL)
return (0);
if (!options_get_number(w->options, "monitor-bell"))
return (0);
TAILQ_FOREACH(wl, &w->winlinks, wentry)
wl->session->flags &= ~SESSION_ALERTED;

View File

@ -654,6 +654,12 @@ const struct options_table_entry options_table[] = {
.default_num = 0
},
{ .name = "monitor-bell",
.type = OPTIONS_TABLE_FLAG,
.scope = OPTIONS_TABLE_WINDOW,
.default_num = 1
},
{ .name = "monitor-silence",
.type = OPTIONS_TABLE_NUMBER,
.scope = OPTIONS_TABLE_WINDOW,

20
tmux.1
View File

@ -2567,7 +2567,9 @@ The default is zero.
.It Xo Ic bell-action
.Op Ic any | none | current | other
.Xc
Set action on window bell.
Set action on a bell in a window when
.Ic monitor-bell
is on.
The values are the same as those for
.Ic activity-action .
.It Ic default-command Ar shell-command
@ -2928,7 +2930,9 @@ If set to both, a bell and a message are produced.
.It Xo Ic visual-bell
.Op Ic on | off | both
.Xc
If on, a message is shown on a bell instead of it being passed through to the
If on, a message is shown on a bell in a window for which the
.Ic monitor-bell
window option is enabled instead of it being passed through to the
terminal (which normally makes a sound).
If set to both, a bell and a message are produced.
Also see the
@ -3086,6 +3090,12 @@ option.
Monitor for activity in the window.
Windows with activity are highlighted in the status line.
.Pp
.It Xo Ic monitor-bell
.Op Ic on | off
.Xc
Monitor for a bell in the window.
Windows with a bell are highlighted in the status line.
.Pp
.It Xo Ic monitor-silence
.Op Ic interval
.Xc
@ -3319,6 +3329,8 @@ See
.Ic monitor-activity .
.It alert-bell
Run when a window has received a bell.
See
.Ic monitor-bell .
.It alert-silence
Run when a window has been silent.
See
@ -3851,8 +3863,8 @@ The flag is one of the following symbols appended to the window name:
.It Sy "Symbol" Ta Sy "Meaning"
.It Li "*" Ta "Denotes the current window."
.It Li "-" Ta "Marks the last window (previously selected)."
.It Li "#" Ta "Window is monitored and activity has been detected."
.It Li "\&!" Ta "A bell has occurred in the window."
.It Li "#" Ta "Window activity is monitored and activity has been detected."
.It Li "\&!" Ta "Window bells are monitored and a bell has occurred in the window."
.It Li "~" Ta "The window has been silent for the monitor-silence interval."
.It Li "M" Ta "The window contains the marked pane."
.It Li "Z" Ta "The window's active pane is zoomed."